All products

Overview

For suitable points on all-electric injection-molding machines, CNC linear guides, ball screws and equipment-approved centralized systems. Balances pumpability and retention without added solid lubricant particles. Confirm speed, load and grease-supply requirements before selection.

Characteristics

  • Balances pumpability and grease retention
  • Fine, uniform grease texture
  • Thermal oxidation and mechanical stability
  • No added solid lubricant particles

Technical data

Product type
Greases
NLGI grade
1
Operating temperature
-25 °C to +180 °C
Viscosity at 40°C
118 mm²/s
Dropping point
258 °C
Typical test data
PropertyNLGI 1Test Method
AppearanceHomogeneous greaseVisual
Kinematic Viscosity (40 °C), mm²/s118ASTM D445
Worked Penetration (25 °C), 0.1 mm330ASTM D217
Dropping Point, °C258ASTM D2265
Oil Separation (100 °C, 24 h), %2.0ASTM D6184
Evaporation Loss (99 °C, 22 h), %1.4ASTM D972
Water Washout (38 °C, 1 h), %5.2ASTM D1264
Copper Strip Corrosion (100 °C, 24 h), Rating1bASTM D4048
Last Non-Seizure Load (PB), N800ASTM D2596
Weld Point (PD), N2250ASTM D2596

Base oil viscosity. Worked penetration: 60 strokes. NLGI grading: ASTM D217.

The above data correspond to latest technology, modifications reserved. This information is intended as a guide and does not necessarily represent a marketing specification. In individual cases tests have to be carried out by the consumer. Further data upon request.

Applications

Suitable points on all-electric injection molding

machines

Linear guides in CNC machining centers

Ball screws and precision sliding components

Equipment-approved centralized lubrication systems

Electric injection moulding & CNC machining centres
Electric injection moulding & CNC machining centres

Use & storage

Check the specified consistency, temperature, speed and load; do not select by brand or controller alone. Use compatible 700 mL bellows cartridges, centralized systems or grease guns; verify grease delivery and relubricate as specified. Remove old grease or verify compatibility before changing products; avoid mixing different grease types. Store sealed in a cool, dry place. Keep out water and contaminants; use promptly after opening.

Health and safety

Based on available information, this product is not expected to produce adverse effects on health when used for the intended application and the recommendations provided in the Safety Data Sheet (SDS) are followed. The SDS is available upon request. Do not use this product for purposes other than the intended application. Take care to protect the environment when disposing of used product.

Related products