ALA-07-00
ALA-07-00 Grease
- NLGI grade
- 00
- Operating temperature
- -25 °C to +180 °C
- Viscosity at 40°C
- 163 mm²/s
Grease
A soft NLGI 0 grease for suitable hydraulic injection-molding points, low-speed guides and centralized lines requiring good flow. Free of solid fillers, it balances pumping and retention. It is not a direct substitute for grease specified for high speed, heavy loads or higher consistency.
| Property | NLGI 0 | Test Method |
|---|---|---|
| Appearance | Homogeneous grease | Visual |
| Kinematic Viscosity (40 °C), mm²/s | 138 | ASTM D445 |
| Worked Penetration (25 °C), 0.1 mm | 370 | ASTM D217 |
| Dropping Point, °C | 255 | ASTM D2265 |
| Oil Separation (100 °C, 24 h), % | 2.6 | ASTM D6184 |
| Evaporation Loss (99 °C, 22 h), % | 1.4 | ASTM D972 |
| Water Washout (38 °C, 1 h), % | 6.2 | ASTM D1264 |
| Copper Strip Corrosion (100 °C, 24 h), Rating | 1b | ASTM D4048 |
| Last Non-Seizure Load (PB), N | 800 | ASTM D2596 |
| Weld Point (PD), N | 2250 | ASTM D2596 |
Base oil viscosity. Worked penetration: 60 strokes. NLGI grading: ASTM D217.
The above data correspond to latest technology, modifications reserved. This information is intended as a guide and does not necessarily represent a marketing specification. In individual cases tests have to be carried out by the consumer. Further data upon request.
Suitable points on hydraulic injection molding machines
Low-speed guides, bearings and pivot joints
Suitable low-pressure centralized lubrication systems
Long grease lines requiring good flow

Use where NLGI 0 is specified; do not directly replace greases specified for high-speed, heavy-load or firmer-consistency duties. Match 700 mL bellows cartridges to the pump; verify delivery at remote points in long-line or low-pressure systems. Remove old grease or verify compatibility before changing products; avoid uncontrolled mixing. Store sealed in a cool, dry place, away from sunlight, moisture and contaminants.
Based on available information, this product is not expected to produce adverse effects on health when used for the intended application and the recommendations provided in the Safety Data Sheet (SDS) are followed. The SDS is available upon request. Do not use this product for purposes other than the intended application. Take care to protect the environment when disposing of used product.
ALA-07-00 Grease